Spiraltherm Graphite S 9584 is a flange seal made from a V-shaped profiled stainless steel tape with spiral-wound graphite middle layer (purity >98 %). The ends of the stainless steel tape are spot-welded.

Advantages

  • Universal industrial grade
  • Easy to handle

Operating range

Pressure: p = 400 bar Temperature

  • Continuous operation:
    t = -200 °C … +550 °C
  • Inert environment:Contact us to discuss higher temperatures

Recommended surface roughness:
RZ = 12.5 ... 50 μm
Chemical resistance: pH = 0 … 14

Sealing parameters
AD Directive B7

  • k0 x KD = 65 x bd
  • k1 = 1,4 x bd

ASME Code

  • Gasket factor: m = 2.5
  • Minimum surface pressure:
    y = 10,000 psi, y = 70 MPa

Materials

  • Filler material: 98% pure graphite
  • Metal spiral: 1.4541 (321) or 1.4571 (316 Ti)
  • 9584/...R variants: Sulfur content <100 ppm, soluble sulfates <100 ppm

Other materials upon request

Standards and approvals

  • TA Luft (9584/GIA only)
  • BAM (on request)
  • Fire-safe API 607 (9584/GIA only)

Recommended applications

Industries

  • Chemical industry
  • Petrochemical industry
  • Power stations

  • Flange connections

  • Pipe connections
  • Valves
  • Heat exchangers
  • Covers and hatches
  • Reactor vessels
  • Process vessels
  • Maintenance seals

Variants

  • 9584/... (98 % pure graphite filler)
  • 9594/... (99,85 % pure graphite filler)
  • 9594/...R (graphite filler with low sulfur < 200 ppm and water soluble sulfate < 100 ppm cont)
  • 9584/...TZ (with additional PTFE-sealing zone, T < 280 °C)
  • 9594/...TZ (with additional PTFE-sealing zone, T < 280 °C)
  • 9595/... (pure PTFE filler, T < 280 °C)
  • 9596/... (mica filler, T < 900 °C)

Notes

Spiraltherm Graphite 9584 gaskets filled with high quality graphite are Fire Safe.

Forms of supply

Rings:
for tongue-and-groove flanges:

  • 9584/NF (standard)
  • 9584/NFR (sulfur content <100 ppm

for tongue-and-groove flanges, with compression curve:

  • 9584/NFS (standard)
  • 9584/NFSR (sulfur content <100 ppm)

for projection and recess flanges:

  • 9584/VR (standard)
  • 9584/VRR (sulfur content <100 ppm)

for projection and recess flanges, with inner ring:

  • 9584/VRI (standard)
  • 9584/VRIR (sulfur content <100 ppm)

for raised-face flanges, with outer ring:

  • 9584/GA (standard)
  • 9584/GAR (sulfur content <100 ppm)
  • for raised-face flanges, with inner and outer ring:
    • 9584/GIA (standard)
    • 9584/GIAR (sulfur content <100 ppm)
  • Manhole Gasket:
    • 9584/MH (standard)
    • 9584/MHR (sulfur content <100 ppm)

Product variants

Spiraltherm Graphite 9584/GA
Spiral wound gasket with outer guide ring.
Standard type for raised face flange connections.

Spiraltherm Graphite 9584/GIA
Spiral wound gasket with inner and outer guide ring. This style offers the best performance for raised-face flange connections.
The inner ring is used to provide:
- Avoid over-compression at elevated seating loads in high pressure service
- Reduced turbulence within the flange area and protects against corrosion or erosion
- Improvement of the load distribution over the gasket

Spiraltherm Graphite 9584/VR
Spiral wound gasket without inner ring or outer guide ring.
Mainly used for male and female flanges or projection and recess flanges.

Spiraltherm Graphite 9584/VRI
Spiral wound gasket with inner ring.
Mainly used for male and female flanges or projection and recess flanges.
An inner ring is necessary as a compression stop.